banner
gallerytech



THE IMPACT SERIES
7.5W TO 100W LOW PROFILE DIN RAIL MOUNT POWER SUPPLIES

LOW PROFILE FOR BUILDING AUTOMATION
- 5V TO 24V OUTPUTS
- WIDE RANGE AC INPUT
- UL1310 CLASS 2(1)
- CLASS II DOUBLE INSULATION
- 25 TO +71°C OPERATION
- CONVECTION COOLED
- DIN RAIL OR CHASSIS MOUNT

FEATURE:

- LOW 2.2” PROFILE
- WIDE RANGE AC
- FULL POWER AT 61°C

BENEFITS:

- FITS INTO WALL MOUNTED CABINETS
- GLOBAL USE WITH NO INPUT SELECTOR SWITCHES
- NO DERATING NEEDED

ITEM#: IL-PS-IMPACT-SERIES


15W AC-DC (12V/1.25A) UNIVERSAL POWER SUPPLY

FEATURES:
- 12V REGULATED OUTPUT
- 1.25 AMPS
- IN LINE EMI/RFI FILTER
- UNIVERSAL AC INPUT 90-264VAC
- LOW RIPPLE NOISE
- NO MINIMUM LOAD REQUIREMENT
- 100% BURN IN TEST
- ENERGY EFFICIENT SWITCHING TECHNOLOGY
- 1.8 METER OUTPUT CORD
- FEMALE PLUG: 5.5 X 2.1MM
- UL, CUL APPROVED

ITEM#: IL-PS-12V-15W



40 WATT 12V/3.5A SINGLE OUTPUT POWER SUPPLY

FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-264VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-150%
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON- CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- COOLING METHOD: CONVECTION
- UL REF. NUMBER: E258719
- EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3,
EN61000-4-2,3,4,5,6,8,11

ITEM# : IL-PS-12V-40W


60 WATT 12V/5A SINGLE OUTPUT POWER SUPPLY

FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-264VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-150%
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- UL REF. NUMBER: E258719
- EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3,
EN61000-4-2,3,4,5,6,8,11
- COOLING METHOD: CONVECTION

ITEM# : IL-PS-12V-60W


100WATT 12V/8.5A SINGLE OUTPUT POWER SUPPLY

FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-132/ 170-264VAC SELECTED BY SWITCH
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-130% CONSTANT CURRENT, AUTO RECOVERY
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON-CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- UL REF. NUMBER: E258719 EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3,
EN61000-4-2,3,4,5,6,8,11
- COOLING METHOD: CONVECTION

ITEM#: IL-PS-12V-100W


150WATT 12V/12.5A SINGLE OUTPUT POWER SUPPLY

FEATURES:
- COMPLIES WITH ROHS DIRECTIVE
- AC INPUT VOLTAGE RANGE: 85-132/ 170-264VAC SELECTED BY SWITCH
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 20A/115V, 40A/230V
- INPUT LEAKAGE CURRENT: <0.7MA/230V
- LINE REGULATION (FULL LOAD): <± 0.5%
- OUTPUT VOLTAGE ADJ. RANGE: ± 10%
- OUTPUT OVERLOAD PROTECTION: 110-130% CONSTANT CURRENT, AUTO RECOVERY
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 3.0KVAC/1MIN; I/P-F/G: 1.5KVAC/1MIN; O/P-F/G: 0.5KVAC/1MIN
- RISE TIME: 50MS@FULL LOAD (TYPICAL)
- HOLD UP TIME: 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP.& HUMIDITY: -10°C TO 50°C (14°F - 122°F), 20%-93%RH (NON-CONDENSING)
- STORAGE TEMP.& HUMIDITY: -20°C TO 85°C (-4°F - 185°F), 20%-93%RH (NON-CONDENSING)
- MTBF: 100,000 HOURS
- UL REF. NUMBER: E258719
- EMC STANDARDS: GB9254, EN55022 CLASSB, EN55024, EN61000-3-2,3, EN61000-4-2,3,4,5,6,8,11
- COOLING METHOD: CONVECTION

ITEM#: IL-PS-12V-150W


12 VOLT 200 WATT SINGLE OUTPUT POWER SUPPLY

- SWITCH ABLE AC INPUT RANGES (85-132VAC & 170-264VAC)
- 12VDC OUTPUT @ 16.5 AMPS
- OVERLOAD (OVER CURRENT) SHORT CIRCUIT PROTECTION
- OVER VOLTAGE PROTECTION
- INTEGRATED COOLING FAN

ITEM#: IL-PS-12V-200W


300 W, 12V/25A SINGLE OUTPUT POWER SUPPLY

FEATURES:
- 300W, 12V/25A
- HIGH RELIABILITY, LOW COST
- BUILT IN FAN SPEED CONTROL
- 100% FULL LOAD BURN-IN TEST
- PROTECTIONS: OVER CURRENT/ OVER VOLTAGE/ OVER TEMPERATURE/ SHORT CIRCUIT
- 1 YEAR WARRANTY
- DIMENSIONS: 9.64 X 4.96 X 2.6”

SPECIFICATIONS:
- AC INPUT VOLTAGE RANGE: 90-130VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 40A
- INPUT LEAKAGE CURRENT: <0.7MA
- LINE REGULATION (FULL LOAD): <±0.5%
- OUTPUT VOLTAGE ADJUST RANGE: ±10%
- OUTPUT OVER CURRENT PROTECTION: 110-130%, CURRENT LIMITING, AUTO RECOVERY
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 1.5KVAC/1MIN: O/P-F/G: 0.5KVAC/1MIN
- RISE, HOLD UP TIME: 50MS, 20MS@FULL LOAD (TYPICAL)
- OPERATING TEMP. & HUMIDITY: -10°C/+50°C, 20%-93%RH (NON-CONDENSING)
- STORAGE TEMP & HUMIDITY: -20°C/+85°C, 20%-95%RH (NON-CONDENSING)
- COOLING METHOD: FAN

ITEM#: IL-PS-12V-300W


500W, 12V/42A SINGLE OUTPUT POWER SUPPLY

FEATURES:
- 500W, 12V/42A
- HIGH RELIABILITY, LOW COST
- BUILT IN EMI FILTER
- 100% FULL LOAD BURN-IN TEST
- PROTECTIONS: OVER CURRENT/ OVER VOLTAGE/ OVER TEMPERATURE/ SHORT CIRCUIT
- 1 YEAR WARRANTY
- DIMENSIONS: 10.0 X 6.4 X 3.48”

SPECIFICATIONS:
- AC INPUT VOLTAGE RANGE: 90-130VAC
- INPUT FREQUENCY: 47-63HZ
- INRUSH CURRENT: COLD START, 60A
- INPUT LEAKAGE CURRENT: <0.7MA
- LINE REGULATION (FULL LOAD): <±0.5%
- OUTPUT VOLTAGE ADJUST RANGE: ±10%
- OUTPUT OVER CURRENT PROTECTION: 110-130%, CURRENT LIMITING, AUTO RECOVERY
- OUTPUT OVER VOLTAGE PROTECTION: 115-150%
- WITHSTAND VOLTAGE: I/P-O/P: 1.5KVAC/1MIN :I/P-F/G: 1.5KVAC/1MIN :O/P-F/G: 0.5KVAC/1MIN
- RISE, HOLD UP TIME: 50MS, 20MS@FULL LOAD (TYPICAL
- OPERATING TEMP. & HUMIDITY: -10°C/+50°C, 20%-90%RH (NON-CONDENSING)
- STORAGE TEMP & HUMIDITY: -20°C/+85°C, 20%-95%RH (NON-CONDENSING)
- COOLING METHOD: FAN

ITEM#: IL-PS-12V-500W


DIMMABLE LED POWER SUPPLY

 

FEATURES:
- ETL CERTIFIED FOR NORTH AMERICA1 AND CE MARKED FOR EUROPE.
- 1 [TESTED TO ANSI/UL 60950-1, CAN/CSA C22.2 NO. 60950-1-03 AND EN 60950-1.
- BREAKTHROUGH SHORT CIRCUIT & OVERLOAD PROTECTION. PATENTED.
- LIMITED POWER SOURCE OUTPUT ALLOWS FOR CLASS 2 WIRING.
- MULTIPLE INPUT VOLTAGES 120 V, 240 V, AND 277 V, 50/60 HZ.
- OUTPUT CONFIGURABLE FOR 12 VDC OR 24 VDC UP TO 60 W.
- CAN BE DIMMED WITH STANDARD HOUSEHOLD DIMMER.
- NO EXTERNAL FUSING REQUIRED.
- CAN WITHSTAND A DIRECT SHORT CIRCUIT IN EXCESS OF 15 DAYS!
- TRANSFORMER FULLY ENCAPSULATED FOR PROTECTION AGAINST THE ELEMENTS.

ITEM#: IL-DIM-60WPS


CLASS 2 SINGLE OUTPUT SWITCHING POWER SUPPLY

 

FEATURES:
- CONSTANT CURRENT MODE POWER SUPPLY
- UNIVERSAL AC INPUT / FULL RANGE
- EPOXY ENCAPSULATED WITH IP67 LEVEL
- WITHSTAND 300VAC SURGE INPUT FOR 5 SECONDS
- PROTECTIONS: SHORT CIRCUIT / OVER CURRENT / OVER VOLTAGE
- FULLY ISOLATED PLASTIC CASE
- COOLING BY FREE AIR CONVECTION
- SMALL AND COMPACT SIZE
- UL1310 CLASS 2 POWER UNIT
- 100% FULL LOAD BURN-IN TEST
- LOW COST, HIGH RELIABILITY
- SUITABLE FOR LED LIGHTING AND MOVING SIGN APPLICATIONS
- 2 YEARS WARRANTY

ITEM#: IL-40W-PS-C2, IL-60W-PS-C2, IL-100W-PS-C2, IL-150W-PS-C2


6 VOLT POWER SUPPLY FOR THE PULSAR™ SYSTEM

- 6’ CARD WITH MOLDED TERMINATION
- OUTPUT: 6VDC/.2A
- TERMINATION: 3.5MM MIN PHONE PLUG

ITEM#: IL-PS-6V-200MA


AC OUTPUT TRANSFORMERS FOR IMPACT LIGHTING’S SIGNATURE™ SYSTEM

- SECONDARY: 12.6VCT, 2A
- 2.0’’(H)X2.35’’(W)X2.1’’(D)
- 2 .9 MTG HOLES

ITEM#: IL-PS-12V-AC-2A


ACCESSORIES


POWER CORD
- POWER CORD TO CONNECT TO OUR POWER SUPPLY

 

 


RCA PLUG
- RCA PLUG TO CONNECT TO OUR POWER SUPPLY AND TO SOME CONTROLLERS

 



icon
DOWNLOAD PDF


Online Catalog


Visual Bubble Walls™

Galaxy Shelves™

Galaxy Star Panel™

Galaxy Domes™

Galaxy Translucent Concrete™

Galaxy System Design Panels™

The LED Mini™

LED Ceiling Light

Galaxy Countertops™

Galaxy Doors™

Galaxy Rocks™

Galaxy Closet Rods™

Linio 360™ Border Light

Galaxy Floor Tiles™

Galaxy Glass Tiles™

Galaxy Screen™

Galaxy Cubes™

Visual Water Walls™

LED Indoor Theater Lighting

Galaxy Fiber Optic Curtain™

Galaxy Meteor Fall™

LED Flood Light Series

Ambient Glow™


ThinGlow™


Fiber Optic Fixtures


Fiber Optic Cables

IL1500 Illuminator


IMP6000 Illuminator


OptiLED™ Illuminator

Infinite™ Scan

Power Supplies


Controllers

Visual Waterfalls



CLICK HERE 



CLICK ON BUTTON TO REGISTER